Flame Retardant Debris Net 8' 6" x 150' call for pricing

 

                                                   click to enlarge  

Colors Available                                Product Features                                               Product Use

Black                                                 Easy To Install                                              Vertical / Horizontal Debris Netting

Blue                                                   Reinforced Buttonhole Attachment            Sand Blast Curtains

White                                                 UV Treated Hi Density Polyethylene          Scaffold Enclosures

Green                                                Will Not Unravel When Cut                          Vision Barrier 

Custom Colors                                Flexible in Severe Temperature                   Wind Protection

                                                         Meets OSHA Requirement                           Protects Pedestrians

Non-Flame Retardant is available but we do not recommend it. OSHA has a Hazard Assessment Clause that may be used to qualify fines should an accident occur. If you are using portable heaters producing a flame you must have fire remediation equipment on hand in case of fire.  

 

City of Boston Fire Marshall Regulations and many other cities and municipalities are adopting these policies

Section 7.12 Temporary Construction

a. Tarpaulins and similar sheet materials used to cover stored materials or as a temporary wall enclosure shall meet requirements for flame resistance established by the Head of the Fire Department. Tarpaulins and similar sheet materials shall be securely fastened against displacement by wind or other forces.

b. At a site for which a permit is issued under Section 7.01, the materials used for scaffolding, hoist-frame platforms, sidewalks, sheds, concrete forms, chutes for debris removal, or other temporary construction shall be constructed of noncombustible material or of wood treated by a pressure-impregnating process which meets fire retardant requirements established by the Head of the Fire Department.

 

********************

 

 

 

 

American Advantage

A PLANK

LVL Scaffold Plank

Advances in American wood science and manufacturing technology contribute to the A PLANK advantage. Douglas-fir a native species of North America was selected for its superior strength-to-weight ratio. Logs are peeled to yield thin sheets of veneer. Each A PLANK consists of multiple layers of veneer graded by strength and density. Naturally occurring wood defects such as knots and slope of grain are dispersed during the lay-up and lamination process for greater consistency and strength compared to solid lumber planks.

The multiple layers of thin DF veneer enhances the structural uniformity and increases the strength and reliability of our American made A PLANK.

Strength and Stiffness Verification

• Every A PLANK is individually proof tested to insure that each plank meets OSHA deflection limits before being branded as a scaffold plank.

• Modulus of Rupture and Modulus of Elasticity are frequently tested throughout the LVL production process in accordance with the requirements of APA-EWS an independent third party inspection agency.

• A PLANK is designed to conform to ANSI A10.8-2001 Loading Requirements.

Applicable Design Standards

• ICBO 1997 Uniform Building Code Structural Laminated Veneer Lumber

• U.S. Occupational Safety and Health Administration, OSHA Scaffold Standards (29 CFR 1910 and 1926)

• ANSI A10.8-2001, Safety Requirements for Scaffolding.

Plank Embossing

• Each plank is permanently embossed with the following:

A PLANK MADE IN USA OSHA APA-EWS 1081 "Production Date" PROOF TESTED SCAFFOLD PLANK

• Scarfed face joints for a smooth flat working surface

• Eased edges for splinter free handling

INGENUITY

PRODUCTIVITY

RELIABILITY

DURABILITY

SAFETY

STRENGTH

SUSTAINABILITY

 

 

ALLOWABLE SPAN TABLE

LIVE LOAD

SECTION 1½" x 9¼"

SINGLE SPAN

2 EQUAL SPANS

50 psf

10’-5"

11’-8"

75 psf

9'-1"

10'-2"

1-Person

10’-5"

12’-4"

2-Person

8'-2"

8'-8"

3-Person

5'-11"

6'-8"

 

 

  A PLANK 2.2E DF Laminated Scaffold Plank
               
               
               
  Loading Simple Span - Dry Use
  Condition 1-1/2" x 9-1/4" 1-1/2" x 9-1/2" 1-1/2" x 11-1/4"
  50 psf 10' - 0" 10' - 0" 10' - 0"
  75 psf 8' - 0" 9' - 0" 9' - 0"
  1-Person 10' - 0" 10' - 0" 10' - 0"
  2-Person 8' - 0" 8' - 0" 9' - 0"
  3-Person 6' - 0" 6' - 0" 7' - 0"
               
               
  Loading 2-Equal Spans 
  Condition 1-1/2" x 9-1/4" 1-1/2" x 9-1/2" 1-1/2" x 11-1/4"
  50 psf 10' - 0" 10' - 0" 10' - 0"
  75 psf 9' - 0" 9' - 0" 9' - 0"
  1-Person 10' - 0" 10' - 0" 10' - 0"
  2-Person 9' - 0" 9' - 0" 10' - 0"
  3-Person 7' - 0" 7' - 0" 8' - 0"
               
               
  Loading Simple Span - Wet Use
  Condition 1-1/2" x 9-1/4" 1-1/2" x 9-1/2" 1-1/2" x 11-1/4"
  50 psf 9' - 0" 9' - 0" 9' - 0"
  75 psf 8' - 0" 8' - 0" 8' - 0"
  1-Person 9' - 0" 9' - 0" 10' - 0"
  2-Person 7' - 0" 7' - 0" 8' - 0"
  3-Person 5' - 0" 5' - 0" 6' - 0"
               
               
  Loading 2-Equal Spans - Wet Use
  Condition 1-1/2" x 9-1/4" 1-1/2" x 9-1/2" 1-1/2" x 11-1/4"
  50 psf 10' - 0" 10' - 0" 10' - 0"
  75 psf 9' - 0" 9' - 0" 9' - 0"
  1-Person 10' - 0" 10' - 0" 10' - 0"
  2-Person 7' - 0" 7' - 0" 9' - 0"
  3-Person 5' - 0" 5' - 0" 6' - 0"
               

 

Notes:

1. Spans are from center-to-center of scaffold supports.

2. The weight of the plank has been included in all calculations, and is included as a "Dead Load"

3. Deflections are limited to L/60 per OSHA requirements.

4. The "Person" load is defined in ANSI A10.8 as a person weighing 200 pounds, carrying 50 pounds of equipment.

    The "1" Person load is applied to mid-span.

    The "2" Person load is applied with each Person load placed 18" to either side of span.

    The "3" Person load is applied with a Person at mid-span, and a Person load at 18" to either side of mid-span.

5. For conditions other than listed above, contact us for assistance.

         Design Values

         Modulus of Elasticity (E): 2,200,200 psi

         Flexural Strength (Fb): 2,900 psi

         Horizontal Shear Stress (Fv): 145 psi

 

XLAM-SCAFFOLD PLANK DESIGN

 

 

 

MSR-SYP-MACHINE STRESS RATED AT THE SAWMILL FOR STRENGTH

ADHESIVE-PUR-POLYURETHANE RESIN-CROSS LINKING-SIMILAR TO EPOXY-EXTERIOR

TESTING:

EACH SCAFFOLD PLANK IS PROOF LOADED AND FINGER JOINT STRESS TESTED USING OUR QUALITY CONTROL PROGRAM AND WACH PLANK IS MEASURED FOR VERIFICATION OF STRENGTH AND STIFFNESS

CLAIMS:

ANSI A 10.8-2001 SAFETY REQUIREMENTS FOR SCAFFOLD PLANK

MEETS OSHA, STANDARDS, OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION REGULATION FOR WOOD FABRICATED SCAFFOLD PLANK

PLANK WEIGHT     3.6 LBS PER FOOT

MODULUS OF RUPTURE: 2,600 PSI.DRY CONDITION LESS THAN 19% MOISTURE CONTENT

1.5 x 9.25 PLANK

TOTAL LOAD OVER SPECIFIC DISTANCE (OSHA RATING) TOTAL LOAD POUNDS

MEDIUM DUTY-TWO PERSON  50PSF  7' SPAN   1-3/8" DEFLECTION

HEAVY DUTY-THREE PERSON 75PSF   5' SPAN      1"DEFLECTION

END SEALER TO PROTECT SCAFFOLD PLANK FROM WICKING MOISTURE

FACE SEALER TO PROTECT SURFACES FROM ABSORBING MOISTURE

 

PROTECTIVE YELLOW LUMBER SEALER, WHY? WHEN LUMBER IS SEALED WITH A FINISH THAT IS DESIGNED TO PREVENT INCREASED MOISTURE CONTENT, THIS ADDS TO LIFE OF THE PRODUCT.  ITS ALSO ADDS TO THE SAFETY ESPECIALLY ON PROJECTS THAT WORK AT NIGHT AND TO IMPROVE THEIR SAFTEY CLASSIFICATION.  THIS ALSO PROTECTS THE MOST IMPORTANT RESOURCE YOUR VALUED EMPLOYEES, THIS MAKES PEOPLE SAFETY CONSCIOUS WHEN THEY HAVE A YELLOW REMINDER OF WHERE THEY ARE ABOVE THE WORK.

 

SAFETY FIRST IS MORE THAN A SAYING.

CUSTOM COLOR............OPTIONAL  NO CHARGE

LONG TERM FACE SEALER TO TO DOUBLE THE USABLE LIFE OF XLAM SCAFFOLD PLANK

TEXTURED ONE OR BOTH SIDES FOR SLIP RESISTANCE

XLAM-SCAFFOLD PLANK, MADE BY STUART XLAM INC.

100% AMERICAN MADE!!!PLEASE CONTACT US WITH ANY QUESTIONS, WE ARE HERE TO SERVE YOU WITH QUALITY XLSAM-SCAFFOLD PLANK

 

WE ALSO SELL LAMINATED PLANK DI-65 FOR , AND THIS PLANK IS OSHA STAMPED AND APPROVED RODDED (STEEL PIN IN EACH END TO PREVENT SPLITTING) AND CLIPPED

 

 

 

call for pricing

SCAFFOLD COMPONENTS

 

This Scaffold List is of our most popular items. Anything you do not see here just give us a call

Example: stair towers have too many sizes and configurations to list

Sidewalk bridge, debris chutes, debris nets, systems scaffolding, material handling carts, casters, pulleys and more. We have virtually any item associated with scaffolding. 

 

 

 

Scaffolding and Accessories              
                   
Frames 1.69 Diameter Tube   13 Guage   Tensile Strength 70,000 lbs.  
Available with V-Lock - Drop Lock - Flip Lock          
6' 4" Walk Thru Frame            
6' 4" Ladder Frame              
2' x 5' Mason Frame                
3' x 5' Mason Frame                
4' x 5' Mason Frame                
5' x 5' Mason Frame              
6' x 5' Mason Frame                
                   
Galvanized Braces   Punched End Hole Design        
5' Span                  
7' Span                  
8' Span                
10' Span                  
                   
Side Arm Brackets                
20" with Saddle Hanger            
30" with Saddle Hanger              
12" with Coupling Pin              
                   
Scaffold Connecting Pin            
Insert Clip              
                   
Guard Rails              
Guard Post with Female Flip Lock          
Wall Tying Component              
Walk Thru Frame Guard Rail Panel          
Post with 18" Ladder            
                   
Galvanized Screw Jacks and Base Plates            
24" with Socket 15" adjustable              
24" with Base Plate 18" adjustable          
24" Extension Base Plate         call for price  
Base Plate Fixed                
Swivel Base Plate                
Curved Base Plate                
                   
Clamps                  
Rigid Clamp                
Swivel Clamp              
                   
Aluminum Walk Board              
 Walkboard with plywood deck 7'            
Walkboard with plywood deck 8'            
Walkboard with plywood deck 10'          
Walkboard with metal deck      7'      

 

   
Walkboard with metal deck      8'            
Walbboard with metal deck      10'          
Custom sizes are available upon request with deposit        
                   
OSHA Rodded and Clipped Scaffold Plank D-65          
8' plank             call for price  
10' plank             call for price  
13' plank             call for price  
16' plank             call for price  
                   
Laminated Scaffold Plank              
8' plank             call for price  
10' plank             call for price  
13' plank             call for price  
16' plank             call for price  
                   
                   
                   
                   
                   

 

Our Plank Has a 2400 Rating

Call For Special Discounts

On Orders of a 100 Piece's or More